Frequency Response Analyzer

The 0305 Frequency Response Analyzer is the right system at the right price for measuring low impedances devices. In no time at all, the 0305 Frequency Response Analyzer will become one of the most valuable research tools in your laboratory. Designed primarily for use in AC impedance evaluation of batteries, supercapacitors, or any where the accuracy of low impedance values is essential.

Sold as a "Turn-Key" system, the FRA comes complete with: Control Data/Interface PC, Maccor's FRA Software, and Cables. Use the 0305 FRA as a "Stand-Alone" instrument or integrate it with an existing or new Maccor battery test systems to provide a combined research tool capable of a wide range of experiments. These include long term cycling, pulse discharging, cyclic voltametry, differential capacity, and frequency response analysis, working with either half or full cell samples.

Eight Position Multiplexer

Problem: You have several experiments that need to be performed at low impedance values, but have somewhere else to be. Solution: Add the optional Eight Position Multiplexer. The FRA Mux allows you to queue several experiments at once. As each device completes its frequency sweep, the next one in the queue is performed until all have been completed.

Features and Functions

  • Easy to set up and simple to operate.

  • No manual adjustments or setting of dials.

  • Set AC signal amplitude in Peak value.

  • Set Range of Frequency Sweep.

  • Set Number of Frequencies per Decade.

  • Set Polarization Voltage prior to commencing Frequency Scans.

  • View Real Time Data.

  • Plot: Nyquist, Bode, Capacitance, Inductance, Impedance Magnitude, Phase Angle, Real Impedance, Imaginary Impedance.

  • Export data for further analyses on commercially available packages such as Z-Plot.


  • Specifications

    Frequency Range:

    1mHz to 100KHz

    AC Impedance Range:

    100 µOhm to 5 kOhm

    Impedance Accuracy:

    ±0.1% of reading or ±0.00005% of full scale whichever is the larger

    AC Signal Amplitude:

    100 µV to 5V

    Maximum Voltage:

    5V peak (AC + DC)

    Maximum Current:

    3000 mA

    Connection:

    4-terminal Kelvin